Home | Company | Contacts
LOGIN | Sign Up

Elcos Finder
Power range PRP kVA
Frequency Hz Volt
Version
Range 50-100 Light
Light
Stage 2
F32 TM1A 
Mechanical
55
50
72
215x100x200
1020
110
14
75
100
Light
Yuchai
Stage 2
YC4D85Z-D20
Electronic
56
51
73
215x100x200
970
110
10.2
75
100
Light
Stage 2
 NEF N45SM1A 
Mechanical
66
60
87
215x100x200
1080
110
11
75
100
Light
Greaves
Stage 1
4G11TG1
Mechanical
66
60
87
215x100x200
1205
110
11
75
100
Light
Stage 1
1103A-33TG2
Mechanical
66
60
87
215x100x200
1060
110
10
75
100
Light
Yuchai
Stage 2
YC4D90Z-D21
Electronic
66
60
86
215x100x200
995
110
9.4
76
101
Light
Stage 2
 NEF N45SM2A 
Mechanical
80
75
108
215x100x200
1160
110
9
75
100
Light
Non emissionato
 NEF N45SM3
Mechanical
90
80
115
215x100x200
1200
110
7.3
75
100
Light
Stage 1
1104A-44TG2
Mechanical
88
80
116
215x100x200
1140
110
8
75
100
Light
Yuchai
Stage 2
YC4A110Z-D20
Electronic
88
80
115
215x100x200
1240
110
8
76
101
Light
Stage 2
 NEF N45TM2A 
Mechanical
110
100
145
215x100x200
1290
110
7
75
100
Light
Greaves
Stage 1
4G11TAG2
Mechanical
110
100
145
215x100x200
1350
110
7
75
100
Light
Stage 2
1104C-44TAG2
Electronic
110
100
145
215x100x200
1330
110
6
75
100
Light
Yuchai
Stage 2
YC4A140L-D20
Electronic
110
100
145
215x100x200
1300
110
6.5
76
101

Features
1500 r.p.m.
Soundproofed Protection canopy
Removable doors with key lock
Residential muffler
Forklift and anti-turnover base frame
Expulsion dumpers with automatic closing
Magneto-thermal protection on alternator
Daily tank
Low fuel, high temperature coolant and low oil pressure automatic shutdown system

On board panels
 

QLE-V (variant + 11)

Applications:
• Emergency to the main
• Self-production
• Construction site
• Rent
   
CONTROLS
• Manual start up and stop
• Automatic start up and stop from AMF
• Emergency stop button
• Main counter command closed
• Genset counter command closed
   
MEASUREMENTS
• Mains voltage RST
• Mains frequency
• Gen set voltage three-phase RST
• Gen set star voltage RN.SN.TN.
• Gen set frequency
• Battery charger voltage
• Fuel level %
• Total operating hours

 



 

PROTECTIONS
• Failed to start/stop
• Low oil pressure
• High temperature
• Generator battery charger
• No fuel fuel level
• Genset overvoltage
• Genset undervoltage
• Genset maximum frequency
• Genset minimum frequency
• Magnetothermal
   
SIGNALS
• Start up/Stop
• Battery connected/charging
• Battery undervoltage
• Battery overvoltage
• Genset connected
• Mains connected
• Mains overvoltage
• Mains undervoltage
• Emergency button pressed
   
OUTLET (sockets)

• MGT 4P on alternator

 




Optionals
Engine
Engine pre-heater 230V
Battery circuit breaker DC
-40 °C engine liquids
1000 hrs spare parts kit
Oil change pump
Feeding
Automatic fuel refilling system on trestle 120 lts
Tank connection 3 way valve
Canopy
Conveyor for vertical expulsion
Raising hook
Electrical accessories
ATS (QC) Automatic transfer switch (only variant +11)
QPE Polyvalent Elcos Panel
Differential protection adjustable


Downloads
Range 50 250 kVA Light
Adobe PDF document (561 kB)




VIEW on



Info
For more informations please contact export@elcos.net

Driven by Innovation
Certifications









Follow us:
Partita IVA: 01084730199 - GENERAL SALES CONDITIONS

Per offrirti il miglior servizio possibile questo sito utilizza cookies. Continuando la navigazione nel sito acconsenti al loro impiego in conformità alla nostra Cookie Policy

Accetta